| Exterior | ||||||||||
| 9.1.1 SUMNER Cavity Checksheet - Timber Frame Exterior | ||||||||||
| Project: | Project: | O.K √ | Req'd √ | Re Check | O.K √ | Re Check | Date of O.K | |||
| Operation: | Operation: Full System for Timber frame Exterior | |||||||||
| Revision: | Revision: F ( Manual 2014/08 ) | |||||||||
| Work Sequence | Level/Zone | |||||||||
| Considerations | Keep timber framing dry. Framing can have a maximum moisture content of no more than 18% to apply the stonework. As such we recommend using Kiln dried timber (14%-16% moisture) and wrapping the building asap. SUMNER Board acts as a rain shield so this should also be put in place asap. | |||||||||
| SUMNER CAVITY | ||||||||||
| 1.0 Framing Checks | ||||||||||
| 1.1 | Check for double stud at window/door openings & internal corners | |||||||||
| 1.2 | Check alignment of framing i.e. Studs & nogs straight and true | |||||||||
| 1.3 | Upper framing aligning with lower framing | |||||||||
| 1.4 | Intermediate studs at centre < 600mm | |||||||||
| 2.0 Air Seal | ||||||||||
| 2.1 | Identify air seal | |||||||||
| 2.1.1 Low wind loading < 1550 kpa, can be building wrap | ||||||||||
| 2.1.2 High wind loading > 1550 kpa, must be SUMNER Board | ||||||||||
| 2.1.3 Fire rated to -/30/30 & < 1550kpa, can be building wrap | ||||||||||
| 2.2 | Roof Flashing | |||||||||
| 2.2.1 Fit lower roof flashings intersecting with upper framing with | ||||||||||
| upstand behind building wrap & stop ended where necessary | ||||||||||
| 2.3 | Building wrap | |||||||||
| 2.3.1 Fixed with staples. Fix blue band (Polyprop Tape) vertically | ||||||||||
| between studs> 300 cts or horizontally between nogs | ||||||||||
| 2.3.2 Repair all cuts & tears with duct tape | ||||||||||
| 2.3.3 Fold in around windows ( 4 sides) | ||||||||||
| 2.3.4 Tape the 4 corners and sill of each opening with SUMNER tape. | ||||||||||
| 2.4 | Rigid backer | |||||||||
| 2.4.1 Fix with 40mm clouts at 300 centres to all nogs & studs | ||||||||||
| 2.4.2 Edge distances; min 15.0mm | ||||||||||
| Corner distances; min 100 & 50 | ||||||||||
| 2.4.3 Perimeter seal with SUMNER Tape | ||||||||||
| 2.4.4 Tape the 4 corners and sill of each opening with SUMNER tape. | ||||||||||
| 3.0 Batten & Flashing | ||||||||||
| 3.1 | Fixings - Tack in place with 40.mm fixings | |||||||||
| 3.2 | Set out horizontal battens | |||||||||
| 3.2.1 Top (set 10.0mm below horizontal protrusion) | ||||||||||
| 3.2.2 Bottom (set flush with bottom plate) | ||||||||||
| 3.2.3 Fit horizontal batten to bottom of full Ht. windows/doors with top | ||||||||||
| of batten flush with top of floor or retro fit aluminium angle | ||||||||||
| 3.3 | Fitting flashings | |||||||||
| 3.3.1 Vermin flashing to bottom batten | ||||||||||
| 3.3.2 Fit head and sill tray flashing over windows (extend past | ||||||||||
| by 50mm) including assembling Stop Ends | ||||||||||
| 3.3.3 Building wrap sits into head flashing | ||||||||||
| 3.4 | Fit off remainder of batten | |||||||||
| 3.4.1 Horizontal above window | ||||||||||
| 3.4.2 Horizontal below window | ||||||||||
| 3.4.3 Vertical at window is set back 10mm | ||||||||||
| 3.4.4 Verticals at all sheet joins | ||||||||||
| 3.4.5 Verticals at all intermediate studs (max 600 cts) | ||||||||||
| 3.4.6 Horizontals at all horizontal joints & nogs | ||||||||||
| 3.4.7 Horizontals at inter-storey reter to specific detail | ||||||||||
| 3.5 | Penetrations | |||||||||
| 3.5.1 Fit meter box using SUMNER tape flash to all 4 sides of penetration | ||||||||||
| 3.5.2 Install all pipe & duct penetrations and seal as with site folded SUMNER tape gasket | ||||||||||
| SUMNER BOARD | ||||||||||
| 4.1 | Fixing Board | |||||||||
| 4.1.1 Sheets to over-sail bottom plate by 50.0mm | ||||||||||
| 4.1.2 Maintain ground clearances. Bottom of sheets to finish 35.0 mm clear | ||||||||||
| of finished deck surface or 100.0 mm clear of paved surfaces | ||||||||||
| or 175.0 mm clear of unpaved surfaces | ||||||||||
| 4.1.3 9.0mm fix with 60mm stainless steel screws | ||||||||||
| 4.1.4 Normal weight system, centres max 220mm to perimeter, centre stud and nogs | ||||||||||
| 4.1.4 Heavy Weight System centres max 180mm to perimeter, centre stud and nogs (SUMNER Otago and Bluestone Series only) | ||||||||||
| 4.1.5 Heads NOT flush with face of sheet - ie leave 2mm proud | ||||||||||
| 4.1.6 Window flashings stop ended ( Sealant if PVC ) | ||||||||||
| 4.1.7. Install Air Seal to window trim gap prior to fixing interior lining | ||||||||||
| CONTROL JOINTS | 4.1.8 Provide for vertical control joints @ 5m centers max, and horizontal control joints at max 8 m centers | |||||||||
| Nominate type: SUMNER Ledgestone Series □ | ||||||||||
| SUMNER Otago Series □ | ||||||||||
| SUMNER Traditional Series □ | ||||||||||
| SUMNER Bluestone Series □ | ||||||||||
| SUMNER Sandstone Series □ | ||||||||||
| NAME OF BUILDER: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ | ||||||||||
| BUILDERS LBP Number: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ | ||||||||||
| PLEASE SIGN HERE | _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ | Date: | ||||||||
| Note: This form is a legal document and you will be held liable for the costs of any failures, whether direct or indirect, due to falsifications in the document. | ||||||||||